top of page

When you need an affordable way to analyze analog waveforms, the Uni-T UTD2152CL is a great choice!

 

Specifications:

150MHz, 2CH, 500MSa/s, Memory Depth: 64kpts, ≥5000wfms/s, 7in display

 

Introducing the Uni-T UTD2152CL Digital Storage Oscilloscope (DSO)

 

Are you an electrical engineering professor looking to enhance your teaching capabilities and provide students with invaluable hands-on experience? Allow us to introduce the Uni-T UTD2152CL Digital Storage Oscilloscope (DSO). This advanced instrument is tailored to your instructional needs, offering a suite of features designed to reinforce key course topics and foster a deeper understanding of electrical engineering concepts.

 

Key Specifications:

  • Bandwidth: 150MHz
  • Analog Channels: 2
  • Real-Time Sample Rate: 500MSa/s
  • Max. Memory Depth: 64kpts
  • Waveform Capture Rate: 5,000wfms/s

 

Empowering Features to Enhance Your Electrical Engineering Courses


Math Function for Signal Processing:
Benefit: Simplify intricate signal calculations, aiding in the teaching of advanced signal processing concepts. Students can use the DSO to visualize signal operations and understand the underlying mathematics, facilitating a deeper grasp of signal processing techniques.


Zoom Function for In-Depth Analysis:
Benefit: Illustrate key concepts such as modulation and demodulation. The zoom function allows students to closely examine modulated signals, helping them understand the effects of noise and distortion on communication systems.


XY Mode (Lissajous Graphics) for Control Systems:
Benefit: Use Lissajous figures to demonstrate feedback control system principles. Students can observe phase differences between input and output signals, reinforcing their understanding of control theory.


AUTO Mode for Circuit Analysis:
Benefit: Simplify circuit analysis demonstrations by quickly configuring the DSO using the AUTO mode. This feature aids students in visualizing circuit behavior and helps them grasp concepts related to circuit analysis and design.


FFT Spectral Analysis for Power Electronics:
Benefit: Teach students about harmonics and distortion in power electronics systems. This feature enables students to analyze the frequency components of voltage and current waveforms, crucial for understanding power quality.


Automatic Parameter Measurement for Precision:
Benefit: Demonstrate accurate measurement techniques using the DSO's automatic parameter measurement functions. This feature helps students learn how to measure parameters like frequency, RMS, and rise/fall times, enhancing their understanding of measurement principles.


Variety of Triggers for Signal Control:
Benefit: Use different trigger settings to teach students about signal synchronization and sampling. This feature allows students to explore the impact of trigger settings on signal acquisition, improving their grasp of digital signal processing concepts.


Alternating Trigger for Multi-Signal Observation:
Benefit: Help students explore and compare signals from different sources simultaneously. This feature is invaluable for laboratory experiments where students need to observe and analyze signals from various components, enhancing their understanding of electronic circuits.


The Uni-T UTD2152CL Digital Storage Oscilloscope (DSO) is your ally in delivering high-quality electrical engineering education. Elevate your courses by integrating this advanced tool and watch as your students gain a deeper understanding of electrical engineering concepts. Acquire the Uni-T UTD2152CL now and revolutionize your teaching approach. Your students' next breakthrough is just a waveform away!

UNI-T UTD2152CL 150MHz 2Ch Digital Storage Oscilloscope DSO

Quantity
  • Please inquire for pricing and availability on the below accessories:

     

    Passive Probes:

     

    UT-P03 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 60MHz, Voltage: 600Vpp

    UT-P04 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 100MHz, Voltage: 600Vpp

    UT-P05 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 200MHz, Voltage: 600Vpp

    UT-P06 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 300MHz, Voltage: 600Vpp

    UT-P07 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 500MHz, Voltage: 600Vpp

    UT-P08A Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 350Mhz, Voltage: 600Vpp

    UT-P20 High Voltage Scope Probe
    Passive Probe, Probe Attenuation: 100:1, Bandwidth (MHz): 250MHz, Voltage: 1500Vpp

    UT-P21 High Voltage Scope Probe
    Probe Attenuation: 1000:1, Bandwidth (MHz): 50MHz, Voltage: DC 15kVrms/AC 10kV

    UT-V23 high Voltage Scope Probe
    Passive Probe, Probe Attenuation: 100:1, Bandwidth (MHz): 100MHz, Voltage: 2000Vpp

     

    Current Probes:

    UT-P40 AC/DC Current Probe
    Voltage: 600Vrms, Output: 50mV/A, 5mV/A, Max A AC: N/A, MAX A DC: 60A, Frequency: DC~100kHz

    UT-P41 AC/DC Current Probe
    Voltage: , Output: 100mV/A, 10mV/A, Max A AC: N/A, MAX A DC: 100A, Frequency: DC~100kHz

    UT-P42 AC/DC Scope Probe
    Voltage: , Output: , Max A AC: , MAX A DC: 200A, Frequency: 150KHz

    UT-P43 Current Probe
    Output: 100mV/A, Max A AC: 20A, MAX A DC: 20A, Frequency: DC~25MHz

    UT-P44 Current Probe
    Output: 50mV/A, Max A AC: 40A, MAX A DC: 40A, Frequency: DC~50MHz

    Differential Probes:

    UT-P30 Differential Scope Probe
    Differential Probe, Probe Attenuation: 10:1/100:1, Bandwidth (MHz): 100MHz, Voltage: ±800Vpp

    UT-P31 Differential Scope Probe
    Probe Attenuation: 10:1/100:1, Bandwidth (MHz): 100MHz, Voltage: ±1500Vpp

    UT-P32 Differential Scope Probe
    Differential Probe, Probe Attenuation: 100:1/1000:1, Bandwidth (MHz): 50MHz, Voltage: ±3000Vpp

    UT-P33 Differential Scope Probe
    Differential Probe, Probe Attenuation: 10:1/100:1, Bandwidth (MHz): 120MHz, Voltage: ±14KVpp

    UT-P35 Differential Scope Probe
    Probe Attenuation: 50:1/500:1, Bandwidth (MHz): 50MHz, Voltage: 130VDC+PeakAC/1300VDC+PeakAC, Accuracy: 2%

    UT-P36 Differential Scope Probe
    Probe Attenuation: 200:1/500:1, Bandwidth (MHz): 100MHz, Voltage: 560VDC+PeakAC/5600VDC+PeakAC, Accuracy: 2%
     

    Other Accessories:
     

    UT-ISOT Isolation Transformer
    Used for Bode Plot analysis. Requires scopes to have MSO2000-S-BODE or MSO3000CS-S-BODE option

    UT-M15 Logic Pod
    16Ch Logic Analyzer Probe Pod for MSO and UPO Series mixed-signal oscilloscopes