Elevate your test bench with the X-Factor. This 200MHz, 9-in-1 instrument is designed to be the centerpiece of your test setup, featuring a high sample rate, deep memory, and an intuitive touchscreen. Right out of the box, the MSO2000X functions as a Digital Phosphor Oscilloscope, Spectrum Analyzer, Digital Voltmeter, High-Precision Frequency Counter, and Protocol Analyzer. You can easily expand its capabilities by adding a 16-channel Logic Analyzer, 2-channel 50MHz Waveform Generator, Bode Plot Analyzer, and Power Analyzer—all at an affordable price. Plus, enjoy peace of mind with our complimentary warranty extension, providing up to 5 years of worry-free use.

 

Your MSO2000X also includes a built-in 7-digit hardware frequency counter, offering adjustable refresh times and a summary counter feature. The Ultra Phosphor 3.0 display architecture helps you detect elusive signals with ease, supported by true multi-window functionality that allows for up to four independently timed windows, which can be arranged to your preference. The MSO2000X offers 54 types of measurements, with the ability to display 27 simultaneously, and provides measurement statistics through histograms or tendency charts.

 

For waveform calculations, standard math operations and digital filters (high, low, band-pass, band-limit) are included. Expand your capabilities by adding the UT-M15 logic probes for 16 channels of digital logic analysis, or unlock the built-in dual-channel, 50MHz arbitrary function generator with the MSO2000X-AWG option. This enables Bode Plot analysis (with MSO2000X-BODE) and Power Analysis, including Power Quality, Harmonic Analysis, Ripple Wave Analysis, Loop Analysis, and Safe Operation Area analysis (with MSO2000X-PWR).

 

Additional bus triggering and decoding options are available, including CAN, CAN-FD, FlexRay, SENT, and more, either individually or in cost-saving bundles. The new Autoset function uses a fast fuzzy algorithm with multi-channel parallel processing to quickly and accurately detect signal amplitudes and frequencies, dramatically improving efficiency. Enhanced navigation and search capabilities allow you to capture and analyze tens of thousands of waveforms in a single capture, with customizable search conditions and advanced analysis functions. The MSO2000X can be controlled via SCPI standard protocols, Python, and Labview, and features a built-in web server for remote operation.

 

With a user-friendly interface combining a 10.1-inch multi-touch screen and traditional controls, this device ensures efficient operation. Easily upgradeable to 200MHz or 300MHz if your bandwidth needs change, it also offers a variety of connectivity options: USB 3.0 Host x 3, USB 3.0 Device, LAN, AUX Out, Generator Out x 2, 10MHz Reference Input, 10MHz Reference Output, and HDMI. The MSO2000X is certified by cETLus, CE, ROHS, and UKCA.

UNI-T MSO2204X 200MHz 4Ch Mixed Signal Oscilloscope

$1,899.00Price
  • 200 MHz, 4+16 CH, MSO ready, Max. 5 GSa/s, Memory depth: 100 Mpts, 500,000 wfm/s, 10.1" Touch Screen

  • Please inquire for pricing and availability on the below options and accessories:

    Software Options:

    MSO/UPO2000-AUTO
    Function and application bundle option, for MSO/UPO2000 series,including MSO/UPO-CAN, MSO/UPO-CAN FD, MSO/UPO-LIN, MSO/UPO-FlexRay

    MSO/UPO2000-BND
    Function and application bundle option for MSO/UPO2000 series, includes MSO/UPO-EMBD bundle and MSO/UPO-AUTO bundle

    MSO/UPO2000-CAN
    Auto serial bus trigger and analysis-CAN for MSO/UPO2000 series

    MSO/UPO2000-CAN FD
    Auto serial bus trigger and analysis-CAN FD for MSO/UPO2000 series

    Accessories:

    Passive Probes:

    UT-P03 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 60MHz, Voltage: 600Vpp

    UT-P04 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 100MHz, Voltage: 600Vpp

    UT-P05 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 200MHz, Voltage: 600Vpp

    UT-P06 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 300MHz, Voltage: 600Vpp

    UT-P07 Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 500MHz, Voltage: 600Vpp

    UT-P08A Scope Probe
    Passive Probe, Probe Attenuation: 10:1, Bandwidth (MHz): 350Mhz, Voltage: 600Vpp

    UT-P20 High Voltage Scope Probe
    Passive Probe, Probe Attenuation: 100:1, Bandwidth (MHz): 250MHz, Voltage: 1500Vpp

    UT-P21 High Voltage Scope Probe
    Probe Attenuation: 1000:1, Bandwidth (MHz): 50MHz, Voltage: DC 15kVrms/AC 10kV

    UT-V23 High Voltage Scope Probe
    Passive Probe, Probe Attenuation: 100:1, Bandwidth (MHz): 100MHz, Voltage: 2000Vpp

    Current Probes:

    UT-P40 AC/DC Current Probe
    Voltage: 600Vrms, Output: 50mV/A, 5mV/A, Max A AC: N/A, MAX A DC: 60A, Frequency: DC~100kHz

    UT-P41 AC/DC Current Probe
    Voltage: , Output: 100mV/A, 10mV/A, Max A AC: N/A, MAX A DC: 100A, Frequency: DC~100kHz

    UT-P42 AC/DC Scope Probe
    Voltage: , Output: , Max A AC: , MAX A DC: 200A, Frequency: 150KHz

    UT-P43 Current Probe
    Output: 100mV/A, Max A AC: 20A, MAX A DC: 20A, Frequency: DC~25MHz

    UT-P44 Current Probe
    Output: 50mV/A, Max A AC: 40A, MAX A DC: 40A, Frequency: DC~50MHz

    Differential Probes:

    UT-P30 Differential Scope Probe
    Differential Probe, Probe Attenuation: 10:1/100:1, Bandwidth (MHz): 100MHz, Voltage: ±800Vpp

    UT-P31 Differential Scope Probe
    Differential Probe, Probe Attenuation: 10:1/100:1, Bandwidth (MHz): 100MHz, Voltage: ±1500Vpp

    UT-P32 Differential Scope Probe
    Differential Probe, Probe Attenuation: 100:1/1000:1, Bandwidth (MHz): 50MHz, Voltage: ±3000Vpp

    UT-P33 Differential Scope Probe
    Differential Probe, Probe Attenuation: 10:1/100:1, Bandwidth (MHz): 120MHz, Voltage: ±14KVpp

    UT-P35 Differential Scope Probe
    Differential Probe, Probe Attenuation: 50:1/500:1, Bandwidth (MHz): 50MHz, Voltage: 130VDC+PeakAC/1300VDC

    UT-P36 Differential Scope Probe
    Differential Probe, Probe Attenuation: 200:1/500:1, Bandwidth (MHz): 100MHz, Voltage: 560VDC+PeakAC/5600VDC

    Other Accessories:

    UT-ISOT Isolation Transformer
    Used for Bode Plot analysis. Requires scopes to have MSO2000-S-BODE or MSO3000CS-S-BODE option

    UT-M15 Logic Pod
    16Ch Logic Analyzer Probe Pod for MSO and UPO Series mixed-signal oscilloscopes

    BAG-B3 Carry Bag
    Taking your Uni-Trend Spectrum Analyzer and Digital Oscilloscope out into the field? Carry it safely from location to location with our padded carry bag.