This item is a great condition used Fluke 5820A (5820A-5) Oscilloscope Calibrator. Has installed 5 Channel output. All functions have been performance verified but not formally calibrated. Comes with black hard rolling case, two BNC cables and standard power cable. All pictures are of the actual unit, no accessories or scope included.
This item comes with a 6 Month (180 day) warranty. All functions are guaranteed to work or money will be refunded.
Item is in-stock and located in Texas
International Buyers – Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying. For more information of clarification, please ask.
Will ship worldwide. We make our best efforts to get you the best shipping prices. Contact us for other international rates and we will be pleased to give you a quote. We accept VISA / Mastercard. Paypal is also accepted. Sales to within Canada are subject to 5% GST. Ontario sales subject to 13% HST.
Fluke 5820A Oscilloscope Calibrator 600MHz 5 Channel
The Fluke Model 5820A Oscilloscope Calibrator is a precise instrument that calibrates analog and digital oscilloscopes. Features of the 5820A Calibrator include the following: Automatic meter error calculation. Mult x and Div + keys that change the output value to pre-determined cardinal values for various functions. Programmable entry limits that prevent invalid amounts from being entered. Edge, Leveled Sine, Pulse, Marker, and Wave Generation modes. Accurate oscilloscopic input impedance measurement. Tunnel Diode Pulse compatibility. DC Volt Measure Mode. Current Mode generates both DC and low frequency AC current. 1 ns to 500 ns pulse width capability with skew controlled trigger. External reference. Auxiliary input. 5-channel output (5-channel option). The 5-channel option allows you to calibrate up to five oscilloscope channels simultaneously without changing cables. Simultaneous output of a signal and a trigger signal. 600 MHz, Leveled Sine wave output. Optional 600 MHz - 2.1 GHz, Leveled Sine wave output with 150 ps fast edge. Standard IEEE-488 (GPIB) interface, complying with ANSI/IEEE Standards 488.1-1987 and 488.2-1987. EIA Standard RS-232-C serial data interface for printing, displaying, or transferring internally stored calibration constants, and for remote control of the 5820A. Pass-through RS-232-C serial data interface for communicating with the Unit Under Test (UUT). Extensive automatic internal self testing and diagnostics of analog and digital functions. The 5820A Calibrator may be operated at the front panel in the local mode, or remotely using RS-232 or IEEE-488 ports. For remote operations, several software options are available to integrate 5820A operation into a wide variety of calibration requirements. Options. The 5820A-5 option allows you to operate up to five oscilloscope channels without changing cables. The GHz option extends the ranges of the Leveled Sine Wave and Time Marker functions as follows: Leveled Sine Wave frequency range is increased from 600 MHz to 2.1 GHz. Time Marker function smallest period is decreased from 2 ns to 500 ps.
Voltage DC
Range: 0 to ±6.6V (50Ω)
Range: ±0.25%
------------
Range: 0 to ±130V (1 MΩ)
Best 1 Year Specification: ±0.025%
Voltage AC (Squarewave)
Range: : 0 to ±6.6V (50Ω)
Best 1 Year Specification: ±0.25%
--------
Range ±1 mV to ±130V p-p (1 MΩ)
Best 1 Year Specification: ±0.05%
Fast Edge
Range: 4 mV to 2.5V p-p (50Ω)
Best 1 Year Specification (std mainframe): : £ 300 ps Rise Time
Leveled Sinewave
Range: 50 kHz to 600MHz
Best 1 Year Specification(std Mainframe): 50 kHz to 600 MHz
±1.5% Flatness
Time Markers
Range: 5s to 500 ps
Spike, square, 20% pulse, sine
Best 1 Year Specification: ±1 ppm
Wave Generator
Range: Range: 1.8 mV to 55V p-p (1 MΩ)
1.8 mV to 2.5V p-p (50Ω)
0.01 Hz to 100 kHz
Square, Sine, Triangle
Best 1 Year Specification: ±3
Pulse Generator
Range: 15 mV to 1.5V amplitude
Best 1 Year Specification: ±5%
--------
Range: 1 ns to 500 ns width 20 ms to 200 ns period
Best 1 Year Specification: ±0.33 ppm
DC Voltage Measurement
Range: 0 to ±6.6V
Best 1 Year Specification: ±0.05%
Current DC
Range: ±100 mA to ±100 mA
Best 1 Year Specification: ± 0.25%
Current AC
Range: 100 mA p-p to 100 mA p-p
10 Hz to 100 kHz
Squarewave
Best 1 Year Specification: ±0.25%
TV Trigger
NTSC, SECAM, PAL, PAL-M
Input Impedance Measurement
Range: 40Ω to 1.5 MΩ
Best 1 Year Specification: ±0.1%
--------
Range: 5 pF to 50 pF
Best 1 Year Specification: ±5%
Overload Measurement
5V to 9V (dc or ac squarewave), 5 to 60 seconds