top of page

This item is a good condition used Fluke Fluke 3540 FC 3 Phase Power Monitor. Calibrated to NIST Standards on October 10, 2024. Includes x4 alligator clips, x4 Fluke 1500-12 iFlex Flexible Current Probes (1500A, 12"), Fluke 3 Phase Cable Assembly Voltage Test Leads, magnetic meter hanger, traceable calibration certificate, and 180 day warranty. All pictures are of the actual unit and accessories.

 

This item comes with a 6 Month (180 day) warranty. Every pre-owned unit we offer goes through meticulous inspection and NIST calibration to guarantee its reliability and durability.

 

We Calibrate your Test Equipment! Contact us for more information on Calibration by visiting stratatek.com/calibration

 

For customers in the USA, all purchases arrive cleared. ALL brokerage or customs fees are prepaid by us.  Your item arrives FOB destination.

 

International Buyers Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying. For more information of clarification, please ask.

 

Will ship worldwide. We make our best efforts to get you the best shipping prices. Contact us for other international rates and we will be pleased to give you a quote. We accept VISA / Mastercard. Paypal is also accepted. Sales to within Canada are subject to 5% GST.  Ontario sales subject to 13% HST.

Fluke 3540 FC 3 Phase Power Monitor Condition Monitor Logger PQA NIST Calibrated

$2,809.00Price
  • The Fluke 3540 FC monitors equipment for changes in key electrical variables. Current, voltage, frequency, and energy consumption fluctuate when machinery experiences excess load. Screen assets for performance or premature wear using the non-invasive 3540 FC.

    • Portable device offers scalable, remote power monitoring solution
    • View power measurements from a safe distance
    • Wirelessly collect real-time power values
    • Make data-driven decisions

    Wiring configurations: 1-Φ, 1-Φ IT, Split-phase, 3-Φ wye, 3-Φ wye IT, 3-Φ wye balanced, 3-Φ delta, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, 3-Φ high leg delta, 3-Φ delta balanced. Currents only (load studies)

    Number of Voltage inputs: 4 (3 phases and neutral)

    Maximum input voltage 1000 Vrms (1700 Vpk) phase to neutral

    Input impedance: 10 MΩ each phase to neutral

    Bandwidth: 42.5 Hz to 3.5 kHz

    Scaling  1:1, variable

    Number of Current inputs:  3, mode selected automatically for attached sensor

    Current sensor output voltage    Clamp    500 mVrms / 50 mVrms; CF 2.8

    Rogowski coil     150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range

    Bandwidth (-3 dB)            42.5 Hz to 3.5 kHz

    Scaling  1:1 and variable

    Data acquisition

    Resolution           16-bit synchronous sampling

    Sampling frequency         10.24 kHz at 50/60Hz, synchronized to mains frequency

    Input signal frequency    Mains 50/60 Hz (42.5 to 69 Hz)

    Data storage      Internal flash memory (not user replaceable)

    Memory size      Typical 1 offline logging session of 1 week with 1 second intervals. The number of possible logging sessions and logging period depends on user requirements.

    Measured parameters    Voltage, current, frequency, THD V, THD A, power, power factor, fundamental power, DPF

    Averaging interval            1 s

    Total harmonic distortion             THD for voltage and current is calculated on 25 harmonics

    Calculated min/max values times

    Voltage Full cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 HZ)

    Current Half cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz)

    Power   200 ms

    Interfaces

    USB-A    Firmware updates, max. supply current: 120 mA

    WiFi

    Supported modes            Direct connection and connection to infrastructure

    Security                WPA2-AES with pre-shared key

    Power supply

    Voltage range    Nominal 100 V to 500 V (85 V min to 550 V max) using safety plug input

    Mains power      Nominal 100 V to 240 V (85 V min to 265 V max) using IEC 60320 C7 input

    Power consumption        Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)

    Standby power  <0.3 W only when powered using IEC 60320 input

    Efficiency            ≥68.2 % (in accordance with energy efficiency regulations)

    Mains frequency              50/60 Hz ±15 %

    Battery power    Li-ion 3.7 V, 9.25 Wh, customer-replaceable

    On-battery runtime         Up to 4 hr (up to 5.5 hr in energy saving mode)

    Charging time    <6 hr

bottom of page