top of page

This item is a great condition used AVO Megger PMM-1 Power Multimeter. Calibrated to NIST standards on May 19, 2022. Includes user manual and standard power cable. All pictures are of the actual unit.


This item comes with a 3 Month (90 day) warranty.  All functions are guaranteed to work or money will be refunded.

 

Please see our other equipment by visiting stratatek.com
 
For customers in the USA, all purchases arrive cleared. ALL brokerage or customs fees are prepaid by us.  Your item arrives FOB destination.

 

International Buyers – Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying. For more information of clarification, please ask.

 

Will ship worldwide. We make our best efforts to get you the best shipping prices. Contact us for other international rates and we will be pleased to give you a quote. We accept VISA / Mastercard. Paypal is also accepted. Sales to within Canada are subject to 5% GST.  Ontario sales subject to 13% HST.

AVO Megger PMM-1 Power Multimeter 3 Phase 650V 100A NIST Calibrated

$0.00Price
  • The Power MultiMeter PMM-1is a next generation multifunction instrument for measuring ac or dc voltage, ac primary and secondary current, power, reactive power, power factor, phase angle and frequency of a single or three-phase electrical system. In the single-phase mode, the PMM-1 is easily configured to measure the amplitude and phase angle between any two voltages and current inputs.

    These measured quantities are then displayed in an enlarged font size for easier reading on a graphic display. In three-phase mode, all measured quantities are displayed simultaneously on a large, easy-toread graphic display.

    Current

    • Direct Input: 0 - 100 Amperes (ac), 0.01% resolution of range
    • Accuracy: ±0.05% of reading, 50/60 Hz
    • From 0.10 - 10A (21°- 25° C) ±0.1% of reading >10 amperes
    • Minimum Current Measurement: 2 mA
    • Burden at 5A: 0.1VA
    • Crest Factor: 3

    Phase Angle

    • 0 - 360.00° or ±0 - 180.00°, 0.01° resolution
    • Accuracy 50/60 Hz: ±0.08° input levels above 30 V and 1.0 amp(1),
    • ±0.5° input levels above 3 Volts and 0.02 amps, ±2° input levels down to 0.002 amps.

    Power

    • ±0 - 100 KW, 0.1% resolution.
    • Accuracy at 50 or 60 Hz: ±0.1% of VA.

    Reactive Power

    • ±0 - 100 KVAR, 0.1% resolution.
    • Accuracy at 50/60 Hz: ±0.1% of VA.

    Frequency component only of a voltage or current

    • 10 - 1000 Hz, 0.01 Hz resolution.
    • Accuracy: ±0.03 Hz.

    Harmonics

    • Measures all harmonics content simultaneously of any selected
    • voltage or current, up to the 49th harmonic.
    • Accuracy: ±5% of reading

    Time

    • 0.000 to 999.999 seconds
    • 0.000 to 9999.9 cycles

    Seconds Mode

    • ±LSD or ±0.005% of reading, whichever is greater when initiated by a dry contact, a DC potential above 5 volts or an AC potential above 115 VAC*.

    Cycles Mode

    • ±0.5 cycle when initiated by a dry contact, a DC potential above 5 volts or an AC potential above 115 VAC.*
    • *AC voltage accuracy is worse at lower voltages and is ±8 ms in worst cases (5 V rms applied just following wave-shape peak).

    Start/Stop Inputs

    • 5-300 Volts (AC or DC) start or stop inputs. AC or DC applied/removed, or dry contact closure or opening